Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/adminm/htdocs/old.a1consult.newsite.side-walk.dk/wp-includes/functions.php on line 6121

Deprecated: Required parameter $postsPerPage follows optional parameter $category in /home/adminm/htdocs/old.a1consult.newsite.side-walk.dk/wp-content/themes/a1-elementor/functions.php on line 317

Deprecated: Required parameter $postsPerPage follows optional parameter $category in /home/adminm/htdocs/old.a1consult.newsite.side-walk.dk/wp-content/themes/a1-elementor/functions.php on line 336

Deprecated: Required parameter $field follows optional parameter $i in /home/adminm/htdocs/old.a1consult.newsite.side-walk.dk/wp-content/plugins/acf-repeater/includes/5-7/acf-repeater-field.php on line 739

Deprecated: Required parameter $post_id follows optional parameter $i in /home/adminm/htdocs/old.a1consult.newsite.side-walk.dk/wp-content/plugins/acf-repeater/includes/5-7/acf-repeater-field.php on line 739

Deprecated: Required parameter $field follows optional parameter $i in /home/adminm/htdocs/old.a1consult.newsite.side-walk.dk/wp-content/plugins/acf-repeater/includes/5-7/acf-repeater-field.php on line 805

Deprecated: Required parameter $post_id follows optional parameter $i in /home/adminm/htdocs/old.a1consult.newsite.side-walk.dk/wp-content/plugins/acf-repeater/includes/5-7/acf-repeater-field.php on line 805
HORSENS, SAMN FORSYNING, OMLÆNGNING AF HOVEDKLOAK – Specialist og rådgiver i havne- og vandbygninger | A1 Consult A/S
Omlægning af hovedkloak_Horsens

HORSENS, SAMN FORSYNING, OMLÆNGNING AF HOVEDKLOAK

A1 Consult har for Samn Forsynings ApS været rådgiver på et kloakprojekt på Frivangsallé i Horsens.
Projektet omhandlede udførelse af kloakseparering.
A1 Consult har været bygherrerådgiver og været involveret i projektet for at hjælpe med håndtering af grundvandsproblemer, som skyldes et meget højt grundvandsspejl, som kan forsage bundbrud.
Derudover har A1 Consult projekteret en byggegrube til etablering af en Ø7500 mm sandfangstank.

Fakta om projektet
• Separering af ca. 1000 m dobbeltledning
• Ledningsdiameter Ø1400 mm
• Grundvandsspejl over terræn
• Sandfangstank Ø7500 mm, etableret 4 m under terræn

Kunde
Samn Forsyning ApS.

Periode
2017-2018

Anlægssum